Otros criterios de desconexión de la Ventilación Mecánica.

 


Trabajo respiratorio (WOB) <7,5 J/l.
Henning RJ, Shubin H, Weil MH: The measurement of the work of breathing for the clinical assessement of ventilator dependence.  Crit Care Med 1977;5:264-268.

Frecuencia respiratoria >35 rpm.
Sahn SA, Lakshminarayan S: Bedside criteria for discontinuation of mechanical ventilation. Chest. 1973;63:1002-1005.

Frecuencia respiratoria/volumen corriente (FR/VT) <100 r/min/l.
Yang KL, Tobin MJ: A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991;324:1445-1450.

Índice presión-tiempo (IPT) <1,5
Rochester DF, Arora NS: Respiratory muscle failure. Med Clin North Am 1983;67:573-597.

P0.1 <6 cm H2O.
Sassoon CSH, Te TT, Mahutte CK, Light R: Airway occlusion pressure. An important indicator for successful weaning in patients with chronic obstructive pulmonary disease. Am Rev Respir Dis 1987;135:107-113.

 

 